Square D

  • BGA26050

    BGA26050

    BGA26050, an SQD Powerpact, type BGA with 2 poles, 600Y/347 VAC, 50 Amp, an 18kA@600V Rating, I-LINE, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 2
    Voltage: 600Y/347 VAC
    AIC: 18kA@600V
    Mount Type: I-LINE
  • BGA16050

    BGA16050

    BGA16050, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 50 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BDP36050

    BDP36050

    BDP36050, an SQD Powerpact, type BDP with 3 poles, 600Y/347 VAC, 50 Amp, a 14kA@600V Rating, Lugs OFF end, Terminal Nut Kit ON end, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 3
    Voltage: 600Y/347 VAC
    AIC: 14kA@600V
    Mount Type: Lugs OFF end, Terminal Nut Kit ON end
  • BDM36050

    BDM36050

    BDM36050, an SQD Powerpact, type BDM with 3 poles, 600Y/347 VAC, 50 Amp, a 14kA@600V Rating, Lugs ON end, Terminal Nut Kit OFF end, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 3
    Voltage: 600Y/347 VAC
    AIC: 14kA@600V
    Mount Type: Lugs ON end, Terminal Nut Kit OFF end
  • BDL46050

    BDL46050

    BDL46050, an SQD Powerpact, type BDL with 4 poles, 600Y/347 VAC, 50 Amp, a 14kA@600V Rating, EverLink Lugs, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 4
    Voltage: 600Y/347 VAC
    AIC: 14kA@600V
    Mount Type: Line and Load Lugs
  • BDL16050

    BDL16050

    BDL16050, an SQD Powerpact, type BDL with 1 pole, 347 VAC, 50 Amp, 18 kA 480Y/277 V AC breaking capacity, EverLink Lugs, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 18kA@277 VAC
    Mount Type: Line and Load Lugs
  • BDF36050

    BDF36050

    BDF36050, an SQD Powerpact, type BDF with 3 poles, 600Y/347 VAC, 50 Amp, a 14kA@600V Rating, no lugs, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 3
    Voltage: 600Y/347 VAC
    AIC: 14kA@600V
    Mount Type: No lugs
  • BDA26050

    BDA26050

    BDA26050, an SQD Powerpact, type BDA with 2 poles, 600Y/347 VAC, 50 Amp, a 14kA@600V Rating, I-LINE, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 2
    Voltage: 600Y/347 VAC
    AIC: 14kA@600V
    Mount Type: I-LINE
  • BDA16050

    BDA16050

    BDA16050, an SQD Powerpact, type BDA with 1 pole, 347 VAC, 50 Amp, 18 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 18kA@277 VAC
    Mount Type: I-LINE
  • HDP36050

    HDP36050

    Square D HDP36050 Molded Case Circuit Breaker. Family Powerpact; Type HDP; 600 Voltage; 3 Pole; 3 Phase; 50 Amp; 18kA@480V AIC; Bolt-On Mounting.

    Amperage: 50
    Family: Powerpact
    Trip Functions: LI
    Frame: H Frame
    Poles: 3
    Voltage: 600
    AIC: 18kA@480V
    Mount Type: Bolt-On
    MSRP: $1,088.00
    $435.50
  • FA26050AC

    FA26050AC

    Square D FA26050AC Molded Case Circuit Breaker. Family I-Line; Type FA; 600 Voltage; 2 Pole; 1 Phase; 50 Amp; 18kA@480V AIC; I-Line Style Plug-In Mounting.

    Amperage: 50
    Family: I-Line
    Trip Functions: LI
    Frame: F Frame
    Poles: 2
    Voltage: 600
    AIC: 18kA@480V
    Mount Type: I-Line Style Plug-In