Fusible

  • AC321RGR

    AC321RGR

    13 INCH L X 11.25 INCH W X 8.75 INCH D SIZE; ARMOR-CLAD[R] BUSWAY USED ON; UL APPROVAL; 240 V VOLTAGE RATING; 30 AMPERE CURRENT RATING; 200 KILOAMPERE AT 240/480 V INTERRUPTING RATING; GROUND STAB, INTERNAL/INTEGRATED; 3 POLE(S); 3 PHASE 3 WIRE CIRCUIT...

    Amperage: 30
    Family: Armor Clad
    Poles: 3
    Voltage: 240
    Type: AC
    AIC: 200kA@240V
  • AC322RGR

    AC322RGR

    13 INCH L X 11.25 INCH W X 8.75 INCH D SIZE; ARMOR-CLAD[R] BUSWAY USED ON; UL APPROVAL; 240 V VOLTAGE RATING; 60 AMPERE CURRENT RATING; 200 KILOAMPERE AT 240/480 V INTERRUPTING RATING; GROUND STAB, INTERNAL/INTEGRATED; 3 POLE(S); 3 PHASE 3 WIRE CIRCUIT...

    Amperage: 60
    Family: Armor Clad
    Poles: 3
    Voltage: 240
    Type: AC
    AIC: 200kA@240V
  • AC323RGR

    AC323RGR

    18.75 INCH L X 11.25 INCH W X 8.75 INCH D SIZE; ARMOR-CLAD[R] BUSWAY USED ON; UL APPROVAL; 240 V VOLTAGE RATING; 100 AMPERE CURRENT RATING; 200 KILOAMPERE AT 240/480 V INTERRUPTING RATING; GROUND STAB, INTERNAL/INTEGRATED; 3 POLE(S); 3 PHASE 3 WIRE...

    Amperage: 100
    Family: Armor Clad
    Poles: 3
    Voltage: 240
    Type: AC
    AIC: 200kA@240V
  • AC324RGR

    AC324RGR

    18.75 INCH L X 16 INCH W X 8.75 INCH D SIZE; ARMOR-CLAD[R] BUSWAY USED ON; UL APPROVAL; 240 V VOLTAGE RATING; 200 AMPERE CURRENT RATING; 200 KILOAMPERE AT 240/480 V INTERRUPTING RATING; GROUND STAB, INTERNAL/INTEGRATED; 3 POLE(S); 3 PHASE 3 WIRE CIRCUIT...

    Amperage: 200
    Family: Armor Clad
    Poles: 3
    Voltage: 240
    Type: AC
    AIC: 200kA@240V
  • FVK322R

    FVK322R

    11.25 INCH W X 8.75 INCH D X 13 INCH H SIZE; FLEX-A-POWER BUSWAY USED ON; UL APPROVAL; 240 V VOLTAGE RATING; 60 AMPERE CURRENT RATING; 10 KILOAMPERE AT 240/480 V INTERRUPTING RATING; 3 POLE(S); 3-PHASE 3-WIRE CIRCUIT CONFIGURATION; CLASS H FUSE TYPE; NO...

    Amperage: 60
    Family: Type FVK
    Poles: 3
    Voltage: 240
    Type: FVK
    AIC: 200kA@240V
  • FVK323R

    FVK323R

    11.25 INCH W X 8.75 INCH D X 18.75 INCH H SIZE; FLEX-A-POWER BUSWAY USED ON; UL APPROVAL; 240 V VOLTAGE RATING; 100 AMPERE CURRENT RATING; 10 KILOAMPERE AT 240/480 V INTERRUPTING RATING; 3 POLE(S); 3-PHASE 3-WIRE CIRCUIT CONFIGURATION; CLASS H FUSE TYPE;...

    Amperage: 100
    Family: Type FVK
    Poles: 3
    Voltage: 240
    Type: FVK
    AIC: 200kA@240V
  • FVK324R

    FVK324R

    18.75 INCH L X 16 INCH W X 8.75 INCH D SIZE; FLEX-A-POWER[R] BUSWAY USED ON; UL APPROVAL; 240 V VOLTAGE RATING; 200 AMPERE CURRENT RATING; 10 KILOAMPERE AT 240/480 V INTERRUPTING RATING; 3 POLE(S); 3 PHASE 3 WIRE CIRCUIT CONFIGURATION; CLASS H FUSE TYPE;...

    Amperage: 200
    Family: Type FVK
    Poles: 3
    Voltage: 240
    Type: FVK
    AIC: 200kA@240V
  • RV321G

    RV321G

    XL-X. BUSWAY USED ON; 250 VAC/VDC VOLTAGE RATING; 30 AMPERE CURRENT RATING; 3 HP AT 250 VAC/VDC (STANDARD, NEC), 7 1/2 HP AT 250 VAC/VDC (MAXIMUM, TIME DELAY) POWER RATING; 3 POLE(S); 3 PHASE 3 WIRE CIRCUIT CONFIGURATION; VACU-BREAK. BRAND; FLOOR...

    Amperage: 30
    Family: XL-X
    Poles: 3
    Voltage: 240
    Type: RV
    AIC: 200kA@240V
  • RV322G

    RV322G

    XL-X. BUSWAY USED ON; 250 VAC/VDC VOLTAGE RATING; 60 AMPERE CURRENT RATING; 7-1/2 HP AT 250 VAC/VDC (STANDARD, NEC), 15 HP AT 250 VAC/VDC (MAXIMUM, TIME DELAY) POWER RATING; 3 POLE(S); 3 PHASE 3 WIRE CIRCUIT CONFIGURATION; VACU-BREAK. BRAND; FLOOR...

    Amperage: 60
    Family: XL-X
    Poles: 3
    Voltage: 240
    Type: RV
    AIC: 200kA@240V
  • RV323G

    RV323G

    XL-X. BUSWAY USED ON; 250 VAC/VDC VOLTAGE RATING; 100 AMPERE CURRENT RATING; 15 HP AT 250 VAC/VDC (STANDARD, NEC), 30 HP AT 250 VAC/VDC (MAXIMUM, TIME DELAY) POWER RATING; 3 POLE(S); 3 PHASE 3 WIRE CIRCUIT CONFIGURATION; VACU-BREAK. BRAND; FLOOR OPERABLE...

    Amperage: 100
    Family: XL-X
    Poles: 3
    Voltage: 240
    Type: RV
    AIC: 200kA@240V
  • RV324G

    RV324G

    XL-X. BUSWAY USED ON; 250 VAC/VDC VOLTAGE RATING; 200 AMPERE CURRENT RATING; 25 HP AT 250 VAC/VDC (STANDARD, NEC), 60 HP AT 250 VAC/VDC (MAXIMUM, TIME DELAY) POWER RATING; 3 POLE(S); 3 PHASE 3 WIRE CIRCUIT CONFIGURATION; VACU-BREAK. BRAND; FLOOR OPERABLE...

    Amperage: 200
    Family: XL-X
    Poles: 3
    Voltage: 240
    Type: RV
    AIC: 200kA@240V
  • RV325G

    RV325G

    XL-X. BUSWAY USED ON; 250 VAC/VDC VOLTAGE RATING; 400 AMPERE CURRENT RATING; 50 HP AT 250 VAC/VDC (STANDARD, NEC), 125 HP AT 250 VAC/VDC (MAXIMUM, TIME DELAY) POWER RATING; 3 POLE(S); 3 PHASE 3 WIRE CIRCUIT CONFIGURATION; VACU-BREAK. BRAND; FLOOR...

    Amperage: 400
    Family: XL-X
    Poles: 3
    Voltage: 240
    Type: RV
    AIC: 200kA@240V