Accessories and Parts

  • GNF325

    GNF325

    GNF325, Siemens, 400 Amp, General Duty Safety Switch, Type Non-Fusible, 240 Volt, 3 Pole, 3 Phase, 3 Wire, NEMA 1 enclosure.

    Amperage: 400
    Family: General Duty
    Poles: 3
    Voltage: 240
    Enclosure Type: Nema 1 - Standard
    Type: Non-Fusible
    AIC: 100kA@240V
  • GNF326

    GNF326

    GNF326, Siemens, 600 Amp, General Duty Safety Switch, Type Non-Fusible, 240 Volt, 3 Pole, 3 Phase, 3 Wire, NEMA 1 enclosure.

    Amperage: 600
    Family: General Duty
    Poles: 3
    Voltage: 240
    Enclosure Type: Nema 1 - Standard
    Type: Non-Fusible
    AIC: 100kA@240V
  • GT-1327 GT-1327

    GT-1327

    GT-1327, Square D, Ground fault CT, neutral sensor, ratio 600:1, Length 31.3 (795), Width 15.2 (386), Window Length 24.0 (610), Window Width 8.5 (216). Used with Bolt Loc Pressure Switches type BPO and BLO up to 4000 A frames

    Amperage: 1200
    Family: Bolt Loc
  • GTP0060U0101

    GTP0060U0101

    General Electric GTP0060U0101 60A Rating Plug for Entelliguard TU Trip Units, May Be Used With 150A Minimum Current Sensor Through 150A Maximum Current Sensor

    Amperage: 60
    Family: Entelliguard
  • GTP0080U0101

    GTP0080U0101

    General Electric GTP0080U0101 80A Rating Plug for Entelliguard TU Trip Units, May Be Used With 150A Minimum Current Sensor Through 150A Maximum Current Sensor

    Amperage: 80
    Family: Entelliguard
    $136.25
  • GTP0080U0103

    GTP0080U0103

    General Electric GTP0080U0103 80A Rating Plug for Entelliguard TU Trip Units, May Be Used With 150A Minimum Current Sensor Through 225A Maximum Current Sensor

    Amperage: 80
    Family: Entelliguard
  • GTP0100U0103

    GTP0100U0103

    General Electric GTP0100U0103 100A Rating Plug for Entelliguard TU Trip Units, May Be Used With 150A Minimum Current Sensor Through 225A Maximum Current Sensor

    Amperage: 100
    Family: Entelliguard
    $136.25
  • GTP0125U0103

    GTP0125U0103

    General Electric GTP0125U0103 225A Rating Plug for Entelliguard TU Trip Units, May Be Used With 150A Minimum Current Sensor Through 225A Maximum Current Sensor

    Amperage: 225
    Family: Entelliguard
    $136.25
  • GTP0150U0104

    GTP0150U0104

    General Electric GTP0150U0104 150A Rating Plug for Entelliguard TU Trip Units, May Be Used With 150A Minimum Current Sensor Through 400A Maximum Current Sensor

    Amperage: 150
    Family: Entelliguard
    $136.25
  • GTP0200U0204

    GTP0200U0204

    General Electric GTP0200U0204 200A Rating Plug for Entelliguard TU Trip Units, May Be Used With 200A Minimum Current Sensor Through 400A Maximum Current Sensor

    Amperage: 200
    Family: Entelliguard
  • GTP0225U0306

    GTP0225U0306

    General Electric GTP0225U0306 225A Rating Plug for Entelliguard TU Trip Units, May Be Used With 225A Minimum Current Sensor Through 600A Maximum Current Sensor

    Amperage: 225
    Family: Entelliguard