Switches

Circuit Breaker Switches & Electric Switches

A circuit breaker switch breaking down can seriously affect production in plant or manufacturing machinery. When this happens, it is important to find the right part and have it delivered quickly. Quality Switchgear has a diverse inventory of hard-to-find, new, reconditioned, refurbished, and even obsolete electric switches for sale to address various needs.

Contact our team to let them know what you need and when you need it. Our emergency services are available 24 hours a day, seven days a week, and we will ensure your electrical issues are solved as quickly as possible. Find what circuit breaker switch you need from our shop; we look forward to getting your power back on.

  • CB0833B120208A9CT

    CB0833B120208A9CT

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed, W/ Blown Fuse Detector With Three Normally On Lights (Trips Switch) and Control Power Transformer

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208ARCT

    CB0833B120208ARCT

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed, W/ Blown Fuse Detector With Three Normally Off Lights (Trips Switch) and Control Power Transformer

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208AXCT

    CB0833B120208AXCT

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed, W/ Blown Fuse Detector With No Lights (Trips Switch) and Control Power Transformer

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208CT

    CB0833B120208CT

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed W/ Control Power Transformer

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208EO

    CB0833B120208EO

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed W/ Electrically Operated Motor

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208G

    CB0833B120208G

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed W/ Ground Fault With Control Power Transformer

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208GAX

    CB0833B120208GAX

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed, W/ Ground Fault With Control Power Transformer and Blown Fuse Detector With No Lights (Trips Switch)

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208GRAX

    CB0833B120208GRAX

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed, W/ Ground Fault With Control Power Transformer, Single-Phase Voltage Relay With Capacitor Trip Device and Blown Fuse Detector With No Lights (Trips Switch)

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208GRAX5

    CB0833B120208GRAX5

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed, W/ Ground Fault With Control Power Transformer, Single-Phase Voltage Relay With Capacitor Trip Device, Blown Fuse Detector With No Lights (Trips Switch) and 1NO/1NC...

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208KG

    CB0833B120208KG

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed, W/ Key Interlock Provisions and Ground Fault With Control Power Transformer

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208PAXC

    CB0833B120208PAXC

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed W/ Blown Fuse Detector With No Lights (Trips Switch)

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V
  • CB0833B120208R

    CB0833B120208R

    800A, 208V, Cutler Hammer, Type CB, Pringle Switch; 3 Pole, 3 Wire, Bottom-Feed W/ Single-Phase Voltage Relay With Capacitor Trip Device

    Amperage: 800
    Family: Pringle
    Poles: 3
    Voltage: 208
    Type: CB
    AIC: 200kA@480V