Molded Case

  • BDL26050

    BDL26050

    BDL26050, an SQD Powerpact, type BDL with 2 poles, 600Y/347 VAC, 50 Amp, a 14kA@600V Rating, EverLink Lugs, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 2
    Voltage: 600Y/347 VAC
    AIC: 14kA@600V
    Mount Type: Line and Load Lugs
    $528.75
  • BDL36050

    BDL36050

    BDL36050, an SQD Powerpact, type BDL with 3 poles, 600Y/347 VAC, 50 Amp, a 14kA@600V Rating, EverLink Lugs, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 3
    Voltage: 600Y/347 VAC
    AIC: 14kA@600V
    Mount Type: Line and Load Lugs
    $765.00
  • BDL46050

    BDL46050

    BDL46050, an SQD Powerpact, type BDL with 4 poles, 600Y/347 VAC, 50 Amp, a 14kA@600V Rating, EverLink Lugs, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 4
    Voltage: 600Y/347 VAC
    AIC: 14kA@600V
    Mount Type: Line and Load Lugs
  • BDM36050

    BDM36050

    BDM36050, an SQD Powerpact, type BDM with 3 poles, 600Y/347 VAC, 50 Amp, a 14kA@600V Rating, Lugs ON end, Terminal Nut Kit OFF end, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 3
    Voltage: 600Y/347 VAC
    AIC: 14kA@600V
    Mount Type: Lugs ON end, Terminal Nut Kit OFF end
  • BDP36050

    BDP36050

    BDP36050, an SQD Powerpact, type BDP with 3 poles, 600Y/347 VAC, 50 Amp, a 14kA@600V Rating, Lugs OFF end, Terminal Nut Kit ON end, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 3
    Voltage: 600Y/347 VAC
    AIC: 14kA@600V
    Mount Type: Lugs OFF end, Terminal Nut Kit ON end
  • BE250

    BE250

    Siemens BE250 Molded Case Circuit Breaker. Family BL Series; Type BLE; 240 Voltage; 2 Pole; 1 Phase; 50 Amp; 10kA@240V AIC; Bolt-On Mounting.

    Amperage: 50
    Family: BL Series
    Trip Functions: LI
    Poles: 2
    Voltage: 240
    AIC: 10kA@240V
    Mount Type: Bolt-On
  • BGA16050

    BGA16050

    BGA16050, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 50 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA26050

    BGA26050

    BGA26050, an SQD Powerpact, type BGA with 2 poles, 600Y/347 VAC, 50 Amp, an 18kA@600V Rating, I-LINE, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 2
    Voltage: 600Y/347 VAC
    AIC: 18kA@600V
    Mount Type: I-LINE
  • BGA36050

    BGA36050

    BGA36050, an SQD Powerpact, type BGA with 3 poles, 600Y/347 VAC, 50 Amp, an 18kA@600V Rating, I-LINE, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 3
    Voltage: 600Y/347 VAC
    AIC: 18kA@600V
    Mount Type: I-LINE
    $1,152.25
  • BGF36050

    BGF36050

    BGF36050, an SQD Powerpact, type BGF with 3 poles, 600Y/347 VAC, 50 Amp, an 18kA@600V Rating, no lugs, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 3
    Voltage: 600Y/347 VAC
    AIC: 18kA@600V
    Mount Type: No lugs
  • BGL16050

    BGL16050

    BGL16050, an SQD Powerpact, type BGL with 1 pole, 347 VAC, 50 Amp, 35 kA 480Y/277 V AC breaking capacity, EverLink Lugs, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: Line and Load Lugs
  • BGL26050

    BGL26050

    BGL26050, an SQD Powerpact, type BGL with 2 poles, 600Y/347 VAC, 50 Amp, an 18kA@600V Rating, EverLink Lugs, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 2
    Voltage: 600Y/347 VAC
    AIC: 18kA@600V
    Mount Type: Line and Load Lugs