Molded Case

  • LMG3V800

    LMG3V800

    LMG3V800, Siemens VL circuit breaker, very high interrupt class Type MG with 3 poles, 480V, 800 Amp, 100kA@480 VAC, lugs not included, and an electronic trip unit, LSIG or 3P/4W, with residual ground fault protection.

    Amperage: 800
    Family: VL
    Trip Functions: LSIG
    Poles: 3
    Voltage: 480
    AIC: 100kA@480
    Mount Type: Feed-Through
  • LMG3V800B

    LMG3V800B

    LMG3V800B, Siemens VL circuit breaker, very high interrupt class Type MG with 3 poles, 480V, 800 Amp, 100kA@480 VAC, Load End Standard Lugs, and an electronic trip unit, LSIG or 3P/4W, with residual ground fault protection.

    Amperage: 800
    Family: VL
    Trip Functions: LSIG
    Poles: 3
    Voltage: 480
    AIC: 100kA@480
    Mount Type: Bolt-On
  • LMG3V800L

    LMG3V800L

    LMG3V800L, Siemens VL circuit breaker, very high interrupt class Type MG with 3 poles, 480V, 800 Amp, 100kA@480 VAC, Line and Load Standard Lugs, and an electronic trip unit, LSIG or 3P/4W, with residual ground fault protection.

    Amperage: 800
    Family: VL
    Trip Functions: LSIG
    Poles: 3
    Voltage: 480
    AIC: 100kA@480
    Mount Type: Bolt-On
  • LMG3W800

    LMG3W800

    LMG3W800, Siemens VL circuit breaker, very high interrupt class Type MG with 3 poles, 480V, 800 Amp, 100kA@480 VAC, lugs not included, and a Model 555 electronic trip unit with LIG or 3P/4W, residual ground fault protection.

    Amperage: 800
    Family: VL
    Trip Functions: LIG
    Poles: 3
    Voltage: 480
    AIC: 100kA@480
    Mount Type: Feed-Through
  • LMG3W800B

    LMG3W800B

    LMG3W800B, Siemens VL circuit breaker, very high interrupt class Type MG with 3 poles, 480V, 800 Amp, 100kA@480 VAC, Load End Standard Lugs, and a Model 555 electronic trip unit with LIG or 3P/4W, residual ground fault protection.

    Amperage: 800
    Family: VL
    Trip Functions: LIG
    Poles: 3
    Voltage: 480
    AIC: 100kA@480
    Mount Type: Bolt-On
  • LMG3W800L

    LMG3W800L

    LMG3W800L, Siemens VL circuit breaker, very high interrupt class Type MG with 3 poles, 480V, 800 Amp, 100kA@480 VAC, Line and Load Standard Lugs, and a Model 555 electronic trip unit with LIG or 3P/4W, residual ground fault protection.

    Amperage: 800
    Family: VL
    Trip Functions: LIG
    Poles: 3
    Voltage: 480
    AIC: 100kA@480
    Mount Type: Bolt-On
  • LMXD63B800

    LMXD63B800

    Siemens LMXD63B800 Molded Case Circuit Breaker. Family Sentron; Type LMXD; 600 Voltage; 3 Pole; 3 Phase; 800 Amp; 50kA@480V AIC; Bolt-On Mounting.

    Amperage: 800
    Family: Sentron
    Trip Functions: LI
    Frame: LMD Frame
    Poles: 3
    Voltage: 600
    AIC: 50kA@480V
    Mount Type: Bolt-On
  • LMXD63S800A

    LMXD63S800A

    Siemens LMXD63S800A Molded Case Circuit Breaker. Family Sentron; Type LMXD; 600 Voltage; 3 Pole; 3 Phase; 800 Amp; 50kA@480V AIC; Bolt-On Mounting.

    Amperage: 800
    Family: Sentron
    Frame: LMD Frame
    Poles: 3
    Voltage: 600
    AIC: 50kA@480V
    Mount Type: Bolt-On
  • LNG3B800

    LNG3B800

    LNG3B800, Siemens VL circuit breaker, very high interrupt class Type LNG, 3 pole, 480V, 800 Amp, 100kA@480 VAC, lugs not included, with thermal magnetic trip unit.

    Amperage: 800
    Family: VL
    Poles: 3
    Voltage: 480
    AIC: 100kA@480
    Mount Type: Bolt-On
  • LNG3B800B

    LNG3B800B

    LNG3B800B, Siemens VL circuit breaker, very high interrupt class Type LNG, 3 pole, 480V, 800 Amp, 100kA@480 VAC, Load End Standard Lugs, with thermal magnetic trip unit.

    Amperage: 800
    Family: VL
    Poles: 3
    Voltage: 480
    AIC: 100kA@480
    Mount Type: Bolt-On
  • LNG3B800L

    LNG3B800L

    LNG3B800L, Siemens VL circuit breaker, very high interrupt class Type LNG, 3 pole, 480V, 800 Amp, 100kA@480 VAC, Line and Load Standard Lugs, with thermal magnetic trip unit.

    Amperage: 800
    Family: VL
    Poles: 3
    Voltage: 480
    AIC: 100kA@480
    Mount Type: Bolt-On
  • LNG3G800

    LNG3G800

    LNG3G800, Siemens VL circuit breaker, very high interrupt class Type NG with 3 poles, 480V, 800 Amp, 100kA@480 VAC, lugs not included, and an Model 586 Electronic trip unit w/ LCD, LSIG, 3P/4W (selectable residual or return type ground fault protection).

    Amperage: 800
    Family: VL
    Trip Functions: LSIG
    Poles: 3
    Voltage: 480
    AIC: 100kA@480
    Mount Type: Feed-Through