Molded Case

  • BGA16030

    BGA16030

    BGA16030, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 30 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 30
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16035

    BGA16035

    BGA16035, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 35 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 35
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16040

    BGA16040

    BGA16040, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 40 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 40
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16045

    BGA16045

    BGA16045, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 45 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 45
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16050

    BGA16050

    BGA16050, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 50 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 50
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16060

    BGA16060

    BGA16060, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 60 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 60
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16070

    BGA16070

    BGA16070, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 70 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 70
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16080

    BGA16080

    BGA16080, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 80 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 80
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16090

    BGA16090

    BGA16090, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 90 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 90
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16100

    BGA16100

    BGA16100, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 100 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 100
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16110

    BGA16110

    BGA16110, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 110 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 110
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE
  • BGA16125

    BGA16125

    BGA16125, an SQD Powerpact, type BGA with 1 pole, 347 VAC, 125 Amp, 35 kA 480Y/277 V AC breaking capacity, I-LINE, with a thermal mag trip unit.

    Amperage: 125
    Family: Powerpact
    Poles: 1
    Voltage: 277 VAC
    AIC: 35kA@277 VAC
    Mount Type: I-LINE